Tier 12 zonesPiezo grid
Duo Reference
For experienced builders: reference PCBs and the best biometrics.
- Coldest water
- ~18.5 °C*
- sleeper in bed, 25 °C room · model 18.3 °C
- Warms to
- 43 °C
- the safety cap, for every kit
- Peltier input
- 230 W
- per zone at full cooling · within 80 % of the supply
- Kit check
- Claims hold
- checked in CI against the thermal model
* Model estimate. No prototype of this kit has been built or measured yet.
Specs from the kit file
| Tier | 1 · reference PCBs |
|---|---|
| Zones | 2 |
| Peltiers per zone | 4 |
| Heatsink | 0.07 K/W per zone (estimate until measured) |
| Current cap | 5 A per Peltier · 20 A per zone |
| Sensing | Piezo grid |
| Power supplies | 24 V 750 W in a closed power module + aux 100 W |
Coldest water by room temperature
| Room | Duo Reference |
|---|---|
| 20 °C room | 16.4 °C 227 W/zone |
| 25 °C room | 18.3 °C 230 W/zone |
| 28 °C room | 19.4 °C 232 W/zone |
| 30 °C room | 20.2 °C 233 W/zone |
What you need, by role
Parts are listed by the job they do. Each role has example parts with a verification status; pick any part that meets the requirement.
Power
- aux_psuSafety
- polarity_relaySafety
- tec_driveSafety
- tec_psuSafety
Control
- control_mcuSafety
- leak_sensorSafety
- temp_sensorsSafety
- thermal_cutoffSafety
Thermal
- cold_plate
- flow_sensorSafety
- heatsink
- pumpSafety
- reservoirSafety
- tec_module
Water mat
- quick_disconnectSafety
- water_matSafety
Sensing
Build this kit
Read the safety concept, complete the commissioning checklist, then tell us how it went. A build report with measurements is the most valuable contribution right now.