Tier 02 zonesPneumatic
Duo Standard
For couples, with our strongest Tier 0 cooling.
- Coldest water
- ~18.8 °C*
- sleeper in bed, 25 °C room · model 18.6 °C
- Warms to
- 43 °C
- the safety cap, for every kit
- Peltier input
- 186 W
- per zone at full cooling · within 80 % of the supply
- Kit check
- Claims hold
- checked in CI against the thermal model
* Model estimate. No prototype of this kit has been built or measured yet.
Specs from the kit file
| Tier | 0 · modules only |
|---|---|
| Zones | 2 |
| Peltiers per zone | 4 |
| Heatsink | 0.07 K/W per zone (estimate until measured) |
| Current cap | 4.5 A per Peltier · 18 A per zone |
| Sensing | Pneumatic |
| Power supplies | 2× 24 V 280 W + 12 V 120 W, plug-in |
Coldest water by room temperature
| Room | Duo Standard |
|---|---|
| 20 °C room | 16.7 °C 183 W/zone |
| 25 °C room | 18.6 °C 186 W/zone |
| 28 °C room | 19.8 °C 188 W/zone |
| 30 °C room | 20.5 °C 189 W/zone |
What you need, by role
Parts are listed by the job they do. Each role has example parts with a verification status; pick any part that meets the requirement.
Power
- aux_psuSafety
- polarity_relaySafety
- tec_driveSafety
- tec_psuSafety
Control
- control_mcuSafety
- leak_sensorSafety
- temp_sensorsSafety
- thermal_cutoffSafety
Thermal
- cold_plate
- flow_sensorSafety
- heatsink
- pumpSafety
- reservoirSafety
- tec_module
Water mat
- quick_disconnectSafety
- water_matSafety
Sensing
Build this kit
Read the safety concept, complete the commissioning checklist, then tell us how it went. A build report with measurements is the most valuable contribution right now.